Retrofit Kit for Schindler lifts

The Retrofit kit is designed to replace the existing TAM and ETMA SCHINDLER system in the easiest and quicker way, with all the existing features still work.
The solution is Plug& Play, with no tools required once the box is open.
The system can be extended with units for TOC, PIT, Under Car, Motor Room, Inductive Loop etc
The kit is made up by 2wires emergency phone, model Helpy 2W-V, for quick installation on the car-top, and specific retrofit prewired cable.
pn:
5HK-301
Services
- Alarm calls and periodic test calls management as per EN81-28
- Telephone numbers: programmable, up to 12
- Supported voice terminals: up to 8 add-on speaking units (32 with auxiliary BUS power supply)
- Digital volume adjustment
- Advanced self-diagnosis system
- Programming modes: local or remote via phone, SMS, PC with e-stant software and USB cable, micro SD Card
- VoIP compatibility: with analog output or ATA adapter
- Alarm sending modes: voice, CLI, SMS, esse-ti protocol, P100
- Voice prompts: menu with 8 languages, customizable with e-stant software
- Alarm ending: with or without entering codes
- Relay: programmable, multifunction
- Technological alarms: absence of 2W handsfree terminal connection, low battery, battery replacement, power supply failure, diagnostics, auxiliary
- Multi-link function: up to 9 autodiallers can be connected over 1 telephone line
- SD Card: extended LOG, firmware update, messages and programming.
Hardware and Software design
and development carried out
at the Esse-ti Research Center.
100% made in Italy.
Compliant: EN 81-80, EN 81-28, EN 81-70
Compliant: EN 81-80, EN 81-28, EN 81-70
TECHNICAL FEATURES
Power supply features
Power supply: 12 VDC nominal, 11,5 VDC min., 14 VDC max.
Power supply: 12 VDC nominal, 11,5 VDC min., 14 VDC max.
Absorption in idle state: 55 mA
Absorption alarm conversation mode: 190 mA
Self-restorable fuse on power supply input
Internal voltages: +1,8 V , +3,3 V, +5 V
Data transmission and signalling system
Built-in Modem v.23: 300-1200 bps FSK
Absorption alarm conversation mode: 190 mA
Self-restorable fuse on power supply input
Internal voltages: +1,8 V , +3,3 V, +5 V
Data transmission and signalling system
Built-in Modem v.23: 300-1200 bps FSK
Type of dialing over external line: DTMFDTMF generator
Telephone line tones recognition: 85 countries
Telephone line tones recognition: 85 countries
Remote programming protocol: proprietary
Service center protocols: P100, Esse-tiOther protocols upon request
Telephone terminations
Connection to public telephone network or universal GSM gateway: terminal block
Local telephone connection: plug RJ11 / terminal block
Built-in speaking unit
Auxiliary microphone inputs: 2
Auxiliary loudspeaker outputs: 1 (to connect max. 2 passive speaking units or loudspeakers)
Voice messages
Telephone terminations
Connection to public telephone network or universal GSM gateway: terminal block
Local telephone connection: plug RJ11 / terminal block
Built-in speaking unit
Auxiliary microphone inputs: 2
Auxiliary loudspeaker outputs: 1 (to connect max. 2 passive speaking units or loudspeakers)
Voice messages
Pre-recorded languages: 8 (Italian / English / German / French / Polish / Portuguese / Spanish / Russian)
Pre-recorded voice messages: 30 minutes, restorable
Messages that support the programming
Alarm messages
Elevator identification message: customizable (max. 25 s)
Courtesy message for the car: multi-language, customizable (max. 25 s)
Messages customization: via computer (via USB-serial cable and software e-stant) / via micro SD card
Messages that support the programming
Alarm messages
Elevator identification message: customizable (max. 25 s)
Courtesy message for the car: multi-language, customizable (max. 25 s)
Messages customization: via computer (via USB-serial cable and software e-stant) / via micro SD card
Input/output
Given alarm indicator light
Received alarm indicator light
Reset pushbutton
Alarm inputs: 1
Customizable inputs (alarm / auxiliary / reset input): 1
Given alarm indicator light
Received alarm indicator light
Reset pushbutton
Alarm inputs: 1
Customizable inputs (alarm / auxiliary / reset input): 1
Filter inputs: 1 (programmable as reset input)
Relay outputs: 1, programmable (max. 250 Vac or 220 Vdc)
Relay outputs: 1, programmable (max. 250 Vac or 220 Vdc)
Outputs (alarm given, alarm received): 2
LED signalling device status: 1
Serial port for PC connection: 1
Micro SD Card slot
Safety systems
EEPROM for data storage under power failure
Built-in NiCd battery for clock data storage
Double watchdog system
Firmware update and programming pattern
LED signalling device status: 1
Serial port for PC connection: 1
Micro SD Card slot
Safety systems
EEPROM for data storage under power failure
Built-in NiCd battery for clock data storage
Double watchdog system
Firmware update and programming pattern
Via computer (via USB-serial cable and software e-stant) / via micro SD card
Additional data
Dimensions: 157x96x28 mm
Additional data
Dimensions: 157x96x28 mm